Products ATEX Weighing ATEX LOAD CELLS Off center

SPO SERIES SINGLE POINT LOAD CELLS

Estimated delivery within 4-7 working days
SKU
SPO SERIES SINGLE POINT LOAD CELLS
Description:

Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 300x300 mm.

ATEX Version

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
  • ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
  • ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
  • The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Download Brochures:
SPO (489.46 kB)

MAIN FEATURES

  • C3 precision class
  • Off center load compensated
  • Aluminium alloy construction
  • Ip67 protection
  • Max. Capacities from 3 TO 40 kg
  • For platforms with dimensions up to 300 X 300 mm
  • Shielded connection cable
  • Oiml certificate available upon request

TECHNICAL FEATURES

  • Minimum load cell verification interval:
  • Vmin = EMax/8.000-15.000
  • Maximum number of verification intervals: nLC = 3000
  • Full Scale Output: 2mV/V +/- 10%
  • Temperature effect on zero:
  • from ±0,0093% F.S./10K to ±0,0175% F.S/10K
  • Temperature effect on full scale output:
  • 0,0117% F.S./10K (-10°C/+20°C) 0,0175% F.S./10K (+20°C/+40°C)
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -10°C/+50°C
  • Maximum tolerated excitation voltage: 15 VDC
  • Input Resistance: 300..500 Ohm
  • Output Resistance: 300..500 Ohm
  • Insulation Resistance: >2000 MOhm
  • Safe Overload: 150% F.S.
  • Ultimate Overload: 300% F.S.
  • 4-wire shielded cable, 40cm long, 3,2mm diameter