Products Load Cell Dini Argeo Compression ATEX Weighing ATEX LOAD CELLS Compression Featured Products

CPX SERIES LOW PROFILE COMPRESSION LOAD CELLS

Estimated delivery within 4-7 working days
SKU
CPX SERIES LOW PROFILE COMPRESSION LOAD CELLS
Description:

Stainless steel compression load cells suitable for weighing tanks and hoppers with the relevant accessories.

ATEX version

The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:

  • ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
  • ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.

The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).

The CCATEX certificate is issued after the checks done by qualified technicians, with the help of specific equipments, for each load cell.

IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

Download Brochures:
CPX (461.55 kB)

MAIN FEATURES

  • CAPACITIES FROM 250 TO 100000 kg
  • CE-M C3 APPROVED, from 2500 to 12500 kg
  • LOW PROFILE
  • GREAT RESISTANCE TO LATERAL FORCES
  • STAINLESS STEEL CONSTRUCTION
  • IP68 PROTECTION, IP69K UPON REQUEST
  • SHIELDED CONNECTION CABLE

TECHNICAL FEATURES

  • Minimum load cell verification interval: Vmin = EMax / 10000
  • Full Scale Output: 2mV/V +/- 0,5%
  • Non-Repeatability: 0,01% F.S.
  • Combined Error 0,05%
  • Temperature effect on zero: 0,02% / 10°C
  • Temperature effect on full scale output: 0,02% / 10°C
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -20°C/+60°C
  • Creep error after 30 minutes: 0,02% F.S.
  • Maximum tolerated excitation voltage: 15 Vdc
  • Input Resistance: 750 ± 10 Ohm
  • Output Resistance: 700 ± 5 Ohm
  • Zero Balance: +/-1% F.S.
  • Insulation Resistance: >5000 MOhm
  • Safe Overload: 120% F.S.
  • 4-wire shielded cable, 5 mm diameter:
    • 5 m long for CPX 250...5000 versions;
    • 10 m long for CPX 7500...100000 versions.