Specifications
    TR-71nw  TR-72nw TR-72nw-H
Measurement Channels   Temperature 2ch(Internal 1ch / External 2ch) Temperature 1ch, Humidity 1ch(External) Temperature 1ch, Humidity 1ch(External)
Sensor   Thermistor Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance

Measurement
Range

Internal Sensor -10 to 60°C  - - - -
External Sensor

-40 to 110°C ( Supplied Sensor )

-60 to 155°C ( Optional Sensor )

0 to 55 °C 10 to 95 %RH -30 to 80 °C 0 to 99 %RH
Accuracy

Avg. ±0.3°C
[ -20 to 80 °C ]
Avg. ±0.5°C
[ -40 to -20 °C / 80 to 110 °C ]

±0.5°C

±5 %RH
[ at 25°C, 50%RH ]

±0.3°C
[ 0 to 50°C ]
±0.5°C
[ all other
temperatures]

±2.5 %RH [ at 25 °C, 10 to 85 %RH ]
±4.0 %RH [ at 25°C, 0 to 10 % or 85 to 99
%RH ]
For temperatures other than 25 °C and
between 0 °C and 80°C, add ±0.1 %RH
per degree difference from 25.
Humidity Hysteresis: ±1.5 %RH or lower
*1

Measurement Resolution 0.1 °C 0.1 °C 1 %RH 0.1°C 0.1 %RH
Responsiveness

Thermal Time Constant:
Approx. 75 sec.
Response Time ( 90% ):
Approx. 190 sec.

Response Time ( 90% ): Approx. 7 min.

 

Response Time ( 90% ): Approx. 7 min. Response Time ( 90% ): Approx. 20 sec.
LCD Display Items Measurements ( fixed or alternating display ), Battery Warning Mark, etc.
Logging Capacity 8,000 data sets ( One data set consists of readings for all channels in that type of unit. )
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode

Endless ( Overwrite oldest data when capacity is full )
One Time ( Stop recording when capacity is full )

Auto-upload Interval Select from 15 choices: OFF (No auto-upload), 1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs.
Communication Interfaces


Wired LAN Communication for TR-7nw
100BASE-TX/10BASE-T ( RJ45 Connector )
Protocol: HTTP *4 , DHCP, DNS
USB Communication
USB 2.0 ( Mini-B connector )

Power AA Alkaline Battery x 2 ( AA Ni-MH batteries may also be used ), USB Bus Power ( 5V 200mA ), PoE IEEE 802.3af ( TR-7nw only )
Battery Life *2

With LAN communication: Approx. 10 days to 1.5 years
(Ex: Approx. 10 days when Auto-upload Interval is 1 min, 1 yr when 1 hr, 1.5 yrs when 12 hrs or more)

Dimensions H 58 mm x W 78 mm x D 26 mm
Weight TR-7nw: Approx. 110 g ( including batteries )
Operating Environment

Temperature -10 to 60 °C
Humidity 90 %RH or less ( no condensation )

Accessories Temperature Sensor ( TR-0106 ) x 2 Temperature/Humidity Sensor ( THA-3001 ) x 1 High Precision Temperature/Humidity Sensor ( HHA-3151 ) x 1
AA Alkaline Battery ( LR6 ) x 2, Registration Code Label, USB Mini-B Cable ( US-15C ), Manual Set ( Warranty Included )
Software Compatible OS *3

TR-7nw for Windows / T&D Graph ( For PC )
Microsoft Windows 8 32 / 64 bit *4
Microsoft Windows 7 32 / 64 bit
Microsoft Windows Vista 32 bit ( SP1 or later )
T&D Thermo ( For Mobile Devices )
Android OS, iOS ( For the compatible versions, please refer to our website. )

Display Languages *5 English

*1: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under
certain circumstances, it may take some time to return to normal measurement capability.
*2: Battery life varies depending upon the frequency of communication, LAN environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a
new battery and are in no way a guarantee of actual battery life.
*3: For installation, it is necessary to have Administrator ( Computer Administrator ) rights.
*4: If you are using Windows 8, please note that our software is designed to be used in "Desktop" mode only.
*5: We recommend using an operating system in the same language as the display language. Operation in different languages is not guaranteed.
The specifications listed above are subject to change without notice.



Features

Automatic Data Upload via LAN
Equipped with a  wired LAN (TR-7nw), the TR-7wf/nw series data loggerscan automatically upload recorded data to “T&D WebStorage Service” at the set interval. “T&D
WebStorage Service” is a cloud service provided by T&D free of charge. It enables the viewing of uploaded data on your PC or mobile device anytime, anywhere.

One and a Half Years of Operation with just Two Batteries
Battery-powered operation means the device can be placed anywhere without the need for AC power.
Depending on the settings, the TR-7wf/nw series can be used continuously for up to 1.5 years before its
batteries need to be replaced.


Get Temperature and Humidity in a Wider Range with Greater Accuracy
TR-72nw-H comes with a high precision temperature/humidity sensor. Features
include a humidity measurement accuracy of ±2.5%, as well as the wide range measurement of
temperature from -30 to 80 °C and humidity from 0 to 99%RH.


Large Logging Capacity: 8000 Data Sets
One data set consists of readings for all channels in that type of unit. If set at a recording interval of 60
minutes, it gives the user one year's worth of measurements.


Easy Operation via Front Buttons
It is possible to start and stop recording, change recording interval, and make the auto-upload setting by
using buttons on the device.


Application Examples
• For managing temperature and humidity in hospitals, museums, and temperature controlled
warehouses
• Performance testing of humidity and heat control in housing
• For managing temperature and humidity in server rooms
• Recording temperature and humidity in subways and train cars