Email
Products ATEX Weighing ATEX LOAD CELLS Tension
STG SERIES TENSION LOAD CELLS
Estimated delivery within 4-7 working days
SKU
STG SERIES TENSION LOAD CELLS
Description:
Tension or Compression approved load cells for the weighing hoppers, tanks, scales with levers, and with other weighing devices.
ATEX VERSION
- The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
- ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
- ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
- The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
- IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

MAIN FEATURES
- C3 precision class
- 17-4 ph stainless steel construction
- IP67 protection
- Max capacities from 100 TO 1000 kg
- Shielded connection cable
- Test certificate available upon request
TECHNICAL FEATURES
- Minimum load cell verification interval:
- Vmin = EMax / 10.000 (for STG500 and STG1000 model);
- Vmin = EMax / 7.000 (for STG100 model)
- Maximum number of verification intervals: nLC = 3000
- Combined error 0,03% of Full Scale Output (F.S.)
- Non-Repeatability: 0,01% F.S.
- Full Scale Output: 3mV/V +/- 0,08%
- Temperature effect on zero: 0,017% /°C
- Temperature effect on full scale output: 0,014% /°C
- Compensated Temperature Range: -10°C/+40°C
- Operating Temperature Range: -35°C/+65°C
- Creep error after 30 minutes: 0,02% F.S.
- Maximum tolerated excitation voltage: 18 VDC
- Input Resistance: 430 ± 60 Ohm
- Output Resistance: 350 ± 3.5 Ohm
- Zero balance: +/-1% F.S.
- Insulation Resistance: >5000 MOhm
- Safe Overload: 150% F.S.
- Ultimate Overload: 300% F.S.
- 4-wire shielded cable, 6m long, 5 mm diameter