Products ATEX Weighing ATEX LOAD CELLS Off center

SPM SERIES SINGLE POINT LOAD CELLS

Estimated delivery within 4-7 working days
SKU
SPM SERIES SINGLE POINT LOAD CELLS
Description:

Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell; maximum platform dimensions of 600x600 mm.

ATEX Version

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
  • ATEX II 1G Ex ia IIC T6 (Ta -20÷+40ºC) TX (Ta -20÷+65ºC)
  • ATEX II 1D tD A20 TXºC (Ta -20÷+40ºC) TXºC (Ta -20÷+65ºC).
  • The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
  • The CCATEX certificate is issued after the checks done by qualified technicians, with the help of specific equipments, for each load cell.
  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Download Brochures:
SPM (497.14 kB)

MAIN FEATURES

  • C3 precision class
  • Off center load compensated
  • Aluminium alloy construction
  • Ip65 protection
  • Max. Capacities from 100 TO 500 kg
  • For platforms with dimensions up to 600 X 600 mm
  • Shielded connection cable
  • Oiml certificate available upon request
  • Test certificate available upon request

TECHNICAL FEATURES

  • Minimum load cell verification interval: Vmin = EMax / 10.000-15.000
  • Maximum number of verification intervals: nLC = 3000
  • Sensitivity: 2mV/V ± 10%
  • Temperature effect on zero:
  • from ±0,0093 % F.S./10K to ± 0,0140 % F.S./10K
  • Temperature effect on Full Span:
  • ±0,0117% F.S./10K (-10°C/+20°C)
  • ±0,0175% F.S./10K (+20°C/+40°C)
  • Compensated Temperature Range: -10°C/+40°C
  • Operating Temperature Range: -10°C/+50°C
  • Creep at nominal load in 30 minutes: 0,01% F.S.
  • Maximum excitation voltage without damage: 15 Vdc
  • Input Resistance: 300..500 Ohm
  • Output Resistance: 300..500 Ohm
  • Insulation Resistance: >2000 MOhm
  • Mechanical limit load in service: 150% F.S.
  • Destructive load: 300% F.S.
  • Deflection at nominal load: <0,5mm
  • 6-wire shielded cable, 3m long, 5mm diameter