MCR-4TC
Measure and record up to four channels in One logger.
By coupling four units together, it is possible to simultaneously record up to 16 channels. This multi-channel battery powered data logger has an SD memory card slot with auto transfer capabilities to ensure your data is not lost when internal memory becomes full. It also comes with a touch panel for easy operation.
MCR-4TC | |
Measurement Channels | Temperature 4ch |
Input Method | Scanning Method, Differential Input, Each Channel Isolated |
Compatible Sensors | Thermocouple: Type K, J, T, S, R |
Measurement Units | °C, °F |
Measurement Range | K -270 to 1370 °C J -210 to 1200 °C T -270 to 400 °C S -50 to 1760 °C R -50 to 1760 °C |
Input Impedance | Approx. 1 M |
Input Frequency | - |
Accuracy (*2) | Thermocouple Measurement (Sensor inaccuracies not included) K, J, T : ±( 0.5 °C + 0.3 % of reading ) at -100°C or above S, R : ±( 1.5 °C + 0.3 % of reading ) at 100°C or above Cold Junction Compensation ±0.5 °C at 10 to 40 °C ±0.8 °C other temperatures within the operating environmentof the logger |
Measurement Resolution | 0.1°C |
Recording Interval | 100, 200, 500 ms. / 1, 2, 5, 10, 15, 20, 30 sec. 1, 2, 5, 10, 15, 20, 30, 60 min. |
Logging Capacity (*3) | When recording 1 channel : up to 960,000 readings/ch When recording 2 channels : up to 480,000 readings/ch When recording 3 channels : up to 320,000 readings/ch When recording 4 channels : up to 240,000 readings/ch |
Recording Mode | Endless ( Overwrite oldest data in the current recording session when capacity is full ) or One Time ( Stop recording when capacity is full ) |
Group Recording | Up to 4 units ( 16 channels ) can be recorded simultaneously. Coupling of MCR-4V and MCR-4TC is possible. (*4) |
LCD Display Items | Measurements, Trend Graph, Battery Level, etc. |
Communication Interfaces | USB Communication |
External Memory | SD Memory Card, SDHC Memory Card (*5) |
Power | AA Alkaline Battery x 2 ( AA Ni-MH batteries may also be used ) AC Adaptor AD-05A2 , USB Power 5V 250mA |
Battery Life (*6) | Approx. 5 to 60 days 4 channels, Instantaneous value recording With AA alkaline batteries |
Input Terminal Preheat Terminal | Screwless Terminals Compatible Wires Single Wire : 0.32 to 0.65 ( AWG 28 - 22 ) Twisted Wire : 0.08 to 0.32 ( AWG 28 - 22 ), 0.12 or more in diameter Stripping Length : 9 to 10 |
Isolation | CH1, CH2, CH3, CH4, and USB are isolated. Battery terminals are not isolated from the CH1-CH4 input terminals. CH1-CH4 Maximum Applied Voltage : ± 50 V Electrical Isolation Resistance : 50M or more ( DC±250 V ) |
Dimensions | H 120mm x W 75mm x D 32mm |
Weight | Approx. 140 g |
Operating Environment | Temperature: 0 to 50°C Humidity: 90 %RH or less ( no condensation ) |
Accessories | AA Alkaline Battery x 2, USB Mini-B Cable US-15C, Software CD-ROM, Card Slot Cover, User's Manual Set ( Warranty Included ) |
Software Compatible OS (*7) | Microsoft Windows 10 32 / 64 bit Microsoft Windows 8 32 / 64 bit Microsoft Windows 7 32 / 64 bit Microsoft Windows Vista 32 bit ( SP1 or later ) Microsoft Windows XP 32 bit ( SP3 or later ) |
Display Languages (*8) | English |
Other |
The .NET Framework 4 Client Profile is required. (*9) |
*1: When “Auto” is selected, measurement range will be automatically changed according to the voltage being measured.
*2: MCR-4TC has superior noise filter, but the measurement may sometimes fluctuate due to strong noise. Especially when the recording interval is set to 200 ms or less, the filtering becomes weaker and hence the fluctuation may become greater.
*3: If the logging capacity is not filled at the end of one recording session, the logger can record up to 30 times.
*4: Group Recording may not be started depending on the recording or measurement interval specifications of the connected Master unit.
*5: Please check the T&D Website for information on memory cards whose operation has been confirmed.
*6: Battery life varies depending upon multiple factors including ambient temperature, recording interval, number of measurement channels, and frequency of data export to a memory card. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
*7: For installation, it is necessary to have Administrator (Computer Administrator) rights.
*8: We recommend using an operating system in the same language as the display language. Operation in different languages is not guaranteed.
*9: During the installation process of the software, if not present, .NET Framework 4 Client Profile will be installed automatically.