LC-4101 - For small capacity weighing applications
For small capacity weighing applications,single point compact load cells
Capacity | Model No. |
600gf | LC4101-G600 |
1.5kgf | LC4101-K1.5 |
3kgf | LC4101-K003 |
6kgf | LC4101-K006 |
15kgf | LC4101-K015 |
Rated capacities....................... 600gf, 1.5kgf, 3kgf, 0kgf,15kgf
Rated output ...............................1mV/V+15/-0%
Maximum deadweight ..............80% of rated capacity
Maximum safe overload ..........300% of rated capacity
Combined error ........................±0.015% of rated output
Creep ..........................................±0.05% of rated output/hour
Zero balance .............................20±5% of rated output
Compensated temperature range.................. -10°C~+40°C/+14°F~+104°F
Recommended excitation voltage .....................12V
Maximum excitation voltage .....................15V
Input terminal resistance....... Approximately 400Ω
Output terminal resistance ...350Ω±5Ω
Insulation resistance .............Greater than 5000MΩ at DC50V
Temperature effect
Zero ...........................................0.004% of rated output/°C
Span ..........................................0.0014% of rated output/ Type.
Platform size ...........................300x300mm/11.8x11.8 inches
Cable length ............................1.5m / 59 inches
- Parallelogram-type construction
- Temperature compensation maintains both zero and span from -10°C~+40°C/+14°F~+104°F
- Deadweight up to 80 % of capacity. Load weight and deadweight up to 180% of capacity
- Moisture proof
- Compact and lightweight
- Can be used for capacities as light as 600g